P802UC- Hollow Cathode Lamp (HCL)- Thermo Fisher / Unicam – Antimony
299.00$Review Product Voltage Requirements Instrument To suit Thermo / Unicam Pin Type / Connectivity Seven (7) Pin ~ Coded Wavelength Primary Wavelength 217.6nm Alternative Wavelengths 206.8 ~ 217.9nm Optical Window material Quartz -
P803 – Hollow Cathode Lamp (HCL) – Arsenic
318.00$Review Product Voltage Requirements Instrument To suit all AAS (Atomic Absorption Spectroscopy Instruments) Pin Type / Connectivity Two (2) Pin ~ Standard Wavelength Primary Wavelength 193.7nm Alternative Wavelengths 189.0 ~ 197.2nm Optical Window material Quartz -
P803C – Hollow Cathode Lamp (HCL) – Agilent Coded – Arsenic
348.00$Instrument To suit Varian / GBC Scientific Pin Type / Connectivity Four (4) Pin ~ Coded Wavelength Primary Wavelength 193.7nm Alternative Wavelengths 189.0 ~ 197.2nm Optical Window material Quartz -
P803S – Super Lamp – Arsenic
469.00$Improvement in Detection Limit 5x times the improvement over standard Hollow Cathode Lamps Wavelength Primary Wavelength 193.7nm Optical Window material Quartz -
P803T – Hollow Cathode Lamp (HCL) – Arsenic [Tubular]
385.00$Review Product Voltage Requirements Instrument To suit all AAS (Atomic Absorption Spectroscopy Instruments) Additional Information Photron's opto-galvanic see-through lamp has been developed for higher intensity then our Standard Range Hollow Cathode Lamps There is no requirement for an additional power supply and suits all AA instruments. Pin Type / Connectivity… -
P803UC – Hollow Cathode Lamp (HCL) – Thermo Fisher / Unicam – Arsenic
358.00$Review Product Voltage Requirements Instrument To suit Thermo / Unicam Pin Type / Connectivity Seven (7) Pin ~ Coded Wavelength Primary Wavelength 193.7nm Alternative Wavelengths 189.0 ~ 197.2nm Optical Window material Quartz -
P805 – Hollow Cathode Lamp (HCL) – Beryllium
417.00$Review Product Voltage Requirements Instrument To suit all AAS (Atomic Absorption Spectroscopy Instruments) Pin Type / Connectivity Two (2) Pin ~ Standard Wavelength Primary Wavelength 234.9nm Alternative Wavelengths None Optical Window material Quartz -
P805C – Hollow Cathode Lamp (HCL) – Agilent Coded – Beryllium
447.00$Instrument To suit Varian / GBC Scientific Pin Type / Connectivity Four (4) Pin ~ Coded Wavelength Primary Wavelength 234.9nm Alternative Wavelengths None Optical Window material Quartz -
P805UC- Hollow Cathode Lamp (HCL)- Thermo Fisher / Unicam – Beryllium
457.00$Review Product Voltage Requirements Instrument To suit Thermo / Unicam Pin Type / Connectivity Seven (7) Pin ~ Coded Wavelength Primary Wavelength 234.9nm Alternative Wavelengths None Optical Window material Quartz -
P806 – Hollow Cathode Lamp (HCL) – Bismuth
272.00$Review Product Voltage Requirements Instrument To suit all AAS (Atomic Absorption Spectroscopy Instruments) Pin Type / Connectivity Two (2) Pin ~ Standard Wavelength Primary Wavelength 223.1nm Alternative Wavelengths 22.8 ~ 227.7nm Optical Window material Quartz -
P806C – Hollow Cathode Lamp (HCL) – Agilent Coded – Bismuth
299.00$Instrument To suit Varian / GBC Scientific Pin Type / Connectivity Four (4) Pin ~ Coded Wavelength Primary Wavelength 223.1nm Alternative Wavelengths 22.8 ~ 227.7nm Optical Window material Quartz -
P806UC- Hollow Cathode Lamp (HCL)- Thermo Fisher / Unicam – Bismuth
299.00$Review Product Voltage Requirements Instrument To suit Thermo / Unicam Pin Type / Connectivity Seven (7) Pin ~ Coded Wavelength Primary Wavelength 223.1nm Alternative Wavelengths 22.8 ~ 227.7nm Optical Window material Quartz -
P807 – Hollow Cathode Lamp (HCL) – Boron
272.00$Review Product Voltage Requirements Instrument To suit all AAS (Atomic Absorption Spectroscopy Instruments) Pin Type / Connectivity Two (2) Pin ~ Standard Wavelength Primary Wavelength 24.8nm Alternative Wavelengths 208.9nm Optical Window material Quartz -
P807C – Hollow Cathode Lamp (HCL) – Agilent Coded – Boron
302.00$Instrument To suit Varian / GBC Scientific Pin Type / Connectivity Four (4) Pin ~ Coded Wavelength Primary Wavelength 24.8nm Alternative Wavelengths 208.9nm Optical Window material Quartz -
P807UC – Hollow Cathode Lamp (HCL) – Thermo Fisher / Unicam – Boron
299.00$Review Product Voltage Requirements Instrument To suit Thermo / Unicam Pin Type / Connectivity Seven (7) Pin ~ Coded Wavelength Primary Wavelength 24.8nm Alternative Wavelengths 208.9nm Optical Window material Quartz -
P808 – Hollow Cathode Lamp (HCL) – Cadmium
272.00$Review Product Voltage Requirements Instrument To suit all AAS (Atomic Absorption Spectroscopy Instruments) Pin Type / Connectivity Two (2) Pin ~ Standard Wavelength Primary Wavelength 228.8nm Alternative Wavelengths 326.1nm Optical Window material Quartz -
P808C – Hollow Cathode Lamp (HCL) – Agilent Coded – Cadmium
302.00$Instrument To suit Varian / GBC Scientific Pin Type / Connectivity Four (4) Pin ~ Coded Wavelength Primary Wavelength 228.8nm Alternative Wavelengths 326.1nm Optical Window material Quartz -
P808UC – Hollow Cathode Lamp (HCL) – Thermo Fisher / Unicam – Cadmium
299.00$Instrument To suit Thermo / Unicam Pin Type / Connectivity Seven (7) Pin ~ Coded Wavelength Primary Wavelength 228.8nm Alternative Wavelengths 326.1nm Optical Window material Quartz -
P809 – Hollow Cathode Lamp (HCL) – Calcium
272.00$Review Product Voltage Requirements Instrument To suit all AAS (Atomic Absorption Spectroscopy Instruments) Pin Type / Connectivity Two (2) Pin ~ Standard Wavelength Primary Wavelength 422.7nm Alternative Wavelengths 239.9nm Optical Window material Quartz -
P809C – Hollow Cathode Lamp (HCL) – Agilent Coded – Calcium
302.00$Instrument To suit Varian / GBC Scientific Pin Type / Connectivity Four (4) Pin ~ Coded Wavelength Primary Wavelength 422.7nm Alternative Wavelengths 239.9nm Optical Window material Quartz -
P809ST – Optogalvanic (See Through Hollow Cathode Lamp HCL) – Calcium
4,400.00$Optogalvanic Lamps or See Through Hollow Cathode Lamps (HCL) are designed to act as a frequency stable reference for high intensity tuneable monochromatic light sources, particularly lasers. Most of the cathode materials used in standard hollow cathode lamps may be used in the “see-through” design. We can also offer a range…