-
P943 – Hollow Cathode Lamp (HCL) to suit Perkin Elmer – Rhenium
499.00$Instrument Perkin Elmer Atomic Absorption Spectrometer (AAS) Pin Type / Connectivity Nine (9) Pin ~ Standard Wavelength Primary Wavelength 346.0nm Alternative Wavelengths 346.5nm Optical Window material Quartz -
P922LL – Hollow Cathode Lamp (HCL) to suit Cableless Perkin Elmer – Hafnium
499.00$Instrument Perkin Elmer Atomic Absorption Spectroscopy (AAnalyst Series of Instruments) Pin Type / Connectivity Four (4) Pin ~ Cableless Notes This lamp also features EPROM for digital coding Wavelength Primary Wavelength 307.8nm Alternative Wavelengths 268.2nm Optical Window material Quartz -
P923LL – Hollow Cathode Lamp (HCL) to suit Cableless Perkin Elmer – Holmium
499.00$Instrument Perkin Elmer Atomic Absorption Spectroscopy (AAnalyst Series of Instruments) Pin Type / Connectivity Four (4) Pin ~ Cableless Notes This lamp also features EPROM for digital coding Wavelength Primary Wavelength 410.4nm Alternative Wavelengths 425.4 ~ 405.4nm Optical Window material Quartz -
P924LL – Hollow Cathode Lamp (HCL) to suit Cableless Perkin Elmer – Indium
499.00$Instrument Perkin Elmer Atomic Absorption Spectroscopy (AAnalyst Series of Instruments) Pin Type / Connectivity Four (4) Pin ~ Cableless Notes This lamp also features EPROM for digital coding Wavelength Primary Wavelength 303.9nm Alternative Wavelengths 325.6 ~ 410.2nm Optical Window material Quartz -
P930LL – Hollow Cathode Lamp (HCL) to suit Cableless Perkin Elmer – Lutetium
499.00$Instrument Perkin Elmer Atomic Absorption Spectroscopy (AAnalyst Series of Instruments) Pin Type / Connectivity Four (4) Pin ~ Cableless Notes This lamp also features EPROM for digital coding Wavelength Primary Wavelength 335.9nm Alternative Wavelengths 356.7 ~ 337.6nm Optical Window material Quartz -
P935LL – Hollow Cathode Lamp (HCL) to suit Cableless Perkin Elmer – Neodymium
499.00$Instrument Perkin Elmer Atomic Absorption Spectroscopy (AAnalyst Series of Instruments) Pin Type / Connectivity Four (4) Pin ~ Cableless Notes This lamp also features EPROM for digital coding Wavelength Primary Wavelength 492.5nm Alternative Wavelengths 463.4nm Optical Window material Quartz -
P937LL – Hollow Cathode Lamp (HCL) to suit Cableless Perkin Elmer – Niobium
499.00$Instrument Perkin Elmer Atomic Absorption Spectroscopy (AAnalyst Series of Instruments) Pin Type / Connectivity Four (4) Pin ~ Cableless Notes This lamp also features EPROM for digital coding Wavelength Primary Wavelength 334.9nm Alternative Wavelengths 405.9 ~ 408.0nm Optical Window material Quartz -
P940LL – Hollow Cathode Lamp (HCL) to suit Cableless Perkin Elmer – Platinum
499.00$Instrument Perkin Elmer Atomic Absorption Spectroscopy (AAnalyst Series of Instruments) Pin Type / Connectivity Four (4) Pin ~ Cableless Notes This lamp also features EPROM for digital coding Wavelength Primary Wavelength 265.9nm Alternative Wavelengths 264.7 ~ 299.8nm Optical Window material Quartz -
P947LL – Hollow Cathode Lamp (HCL) to suit Cableless Perkin Elmer – Samarium
499.00$Instrument Perkin Elmer Atomic Absorption Spectroscopy (AAnalyst Series of Instruments) Pin Type / Connectivity Four (4) Pin ~ Cableless Notes This lamp also features EPROM for digital coding Wavelength Primary Wavelength 429.7nm Alternative Wavelengths 476.0nm Optical Window material Quartz -
P948LL – Hollow Cathode Lamp (HCL) to suit Cableless Perkin Elmer – Scandium
499.00$Instrument Perkin Elmer Atomic Absorption Spectroscopy (AAnalyst Series of Instruments) Pin Type / Connectivity Four (4) Pin ~ Cableless Notes This lamp also features EPROM for digital coding Wavelength Primary Wavelength 391.2nm/td> Alternative Wavelengths 390.8nm Optical Window material Quartz -
P949LL – Hollow Cathode Lamp (HCL) to suit Cableless Perkin Elmer – Selenium
499.00$Instrument Perkin Elmer Atomic Absorption Spectroscopy (AAnalyst Series of Instruments) Pin Type / Connectivity Four (4) Pin ~ Cableless Notes This lamp also features EPROM for digital coding Wavelength Primary Wavelength 196.0nm Alternative Wavelengths 204.0nm Optical Window material Quartz -
P905 – Hollow Cathode Lamp (HCL) to suit Perkin Elmer – Beryllium
500.00$Review Product Voltage Requirements Instrument Perkin Elmer AAS Pin Type / Connectivity Nine (9) Pin ~ Standard Wavelength Primary Wavelength 234.9nm Alternative Wavelengths None Optical Window material Quartz Warranty Photron's warranty information can be viewed here -
P838C – Hollow Cathode Lamp (HCL) – Agilent Coded – Osmium
514.00$Instrument To suit Varian / GBC Scientific Pin Type / Connectivity Four (4) Pin ~ Coded Wavelength Primary Wavelength 290.9nm Alternative Wavelengths 305.9 ~ 426.0nm Optical Window material Quartz -
P858C – Hollow Cathode Lamp (HCL) – Agilent Coded – Thorium
519.00$Instrument To suit Varian / GBC Scientific Pin Type / Connectivity Four (4) Pin ~ Coded Wavelength Primary Wavelength 371.9nm Alternative Wavelengths None Optical Window material Quartz -
P858UC – Hollow Cathode Lamp (HCL) – Thermo Fisher / Unicam – Thorium
524.00$Review Product Voltage Requirements Instrument To suit Thermo / Unicam Pin Type / Connectivity Seven (7) Pin ~ Coded Wavelength Primary Wavelength 371.9nm Alternative Wavelengths None Optical Window material Quartz -
P943LL – Hollow Cathode Lamp (HCL) to suit Cableless Perkin Elmer – Rhenium
524.00$Instrument Perkin Elmer Atomic Absorption Spectroscopy (AAnalyst Series of Instruments) Pin Type / Connectivity Four (4) Pin ~ Cableless Notes This lamp also features EPROM for digital coding Wavelength Primary Wavelength 346.0nm Alternative Wavelengths 346.5nm Optical Window material Quartz -
P838UC- Hollow Cathode Lamp (HCL) – Thermo Fisher / Unicam – Osmium
529.00$Review Product Voltage Requirements Instrument To suit Thermo / Unicam Pin Type / Connectivity Seven (7) Pin ~ Coded Wavelength Primary Wavelength 290.9nm Alternative Wavelengths 305.9 ~ 426.0nm Optical Window material Quartz -
P939LL – Hollow Cathode Lamp (HCL) to suit Cableless Perkin Elmer – Palladium
529.00$Instrument Perkin Elmer Atomic Absorption Spectroscopy (AAnalyst Series of Instruments) Pin Type / Connectivity Four (4) Pin ~ Cableless Notes This lamp also features EPROM for digital coding Wavelength Primary Wavelength 247.6nm Alternative Wavelengths 244.8 ~ 340.5nm Optical Window material Quartz -
P946LL – Hollow Cathode Lamp (HCL) to suit Cableless Perkin Elmer – Ruthenium
529.00$Instrument Perkin Elmer Atomic Absorption Spectroscopy (AAnalyst Series of Instruments) Pin Type / Connectivity Four (4) Pin ~ Cableless Notes This lamp also features EPROM for digital coding Wavelength Primary Wavelength 349.9nm Alternative Wavelengths 392.6nm Optical Window material Quartz -
P858A – Hollow Cathode Lamp (HCL) – Thorium (Argon Gas Fill)
530.00$Review Product Voltage Requirements Instrument To suit all AAS (Atomic Absorption Spectroscopy Instruments) Gas Fill Argon - Used for Spectral Calibiration in Astronomical Industry Pin Type / Connectivity Two (2) Pin ~ Standard Wavelength Primary Wavelength 371.9nm Alternative Wavelengths None Optical Window material Quartz Warranty Photron's warranty information can be… -
P858A – Hollow Cathode Lamp (HCL) – Thorium (Argon Gas Fill)
530.00$Review Product Voltage Requirements Instrument To suit all AAS (Atomic Absorption Spectroscopy Instruments) Gas Fill Argon - Used for Spectral Calibiration in Astronomical Industry Pin Type / Connectivity Two (2) Pin ~ Standard Wavelength Primary Wavelength 371.9nm Alternative Wavelengths None Optical Window material Quartz Warranty Photron's warranty information can be… -
P921C – Hollow Cathode Lamp (HCL) to suit Coded Perkin Elmer – Gold
548.90$Instrument Perkin Elmer Atomic Absorption Spectrocopy Pin Type / Connectivity Twelve (12) Pin ~ Coded Wavelength Primary Wavelength 242.8nm Alternative Wavelengths 267.6nm Optical Window material Quartz -
P925C – Hollow Cathode Lamp (HCL) to suit Coded Perkin Elmer – Iridium
548.90$Instrument Perkin Elmer Atomic Absorption Spectrocopy Pin Type / Connectivity Twelve (12) Pin ~ Coded Wavelength Primary Wavelength 208.9nm Alternative Wavelengths 264.0 ~ 266.5nm Optical Window material Quartz -
P939C – Hollow Cathode Lamp (HCL) to suit Coded Perkin Elmer – Palladium
548.90$Instrument Perkin Elmer Atomic Absorption Spectrocopy Pin Type / Connectivity Twelve (12) Pin ~ Coded Wavelength Primary Wavelength 247.6nm Alternative Wavelengths 244.8 ~ 340.5nm Optical Window material Quartz
















































