P809ST – Optogalvanic (See Through Hollow Cathode Lamp HCL) – Calcium
4,400.00$Optogalvanic Lamps or See Through Hollow Cathode Lamps (HCL) are designed to act as a frequency stable reference for high intensity tuneable monochromatic light sources, particularly lasers. Most of the cathode materials used in standard hollow cathode lamps may be used in the “see-through” design. We can also offer a range… -
P810 – Hollow Cathode Lamp (HCL) – Cesium
313.00$Review Product Voltage Requirements Instrument To suit all AAS (Atomic Absorption Spectroscopy Instruments) Pin Type / Connectivity Two (2) Pin ~ Standard Wavelength Primary Wavelength 852.1nm Alternative Wavelengths 455.6nm Optical Window material Quartz -
P809 – Hollow Cathode Lamp (HCL) – Calcium
272.00$Review Product Voltage Requirements Instrument To suit all AAS (Atomic Absorption Spectroscopy Instruments) Pin Type / Connectivity Two (2) Pin ~ Standard Wavelength Primary Wavelength 422.7nm Alternative Wavelengths 239.9nm Optical Window material Quartz -
P808 – Hollow Cathode Lamp (HCL) – Cadmium
272.00$Review Product Voltage Requirements Instrument To suit all AAS (Atomic Absorption Spectroscopy Instruments) Pin Type / Connectivity Two (2) Pin ~ Standard Wavelength Primary Wavelength 228.8nm Alternative Wavelengths 326.1nm Optical Window material Quartz -
P807 – Hollow Cathode Lamp (HCL) – Boron
272.00$Review Product Voltage Requirements Instrument To suit all AAS (Atomic Absorption Spectroscopy Instruments) Pin Type / Connectivity Two (2) Pin ~ Standard Wavelength Primary Wavelength 24.8nm Alternative Wavelengths 208.9nm Optical Window material Quartz -
P806 – Hollow Cathode Lamp (HCL) – Bismuth
272.00$Review Product Voltage Requirements Instrument To suit all AAS (Atomic Absorption Spectroscopy Instruments) Pin Type / Connectivity Two (2) Pin ~ Standard Wavelength Primary Wavelength 223.1nm Alternative Wavelengths 22.8 ~ 227.7nm Optical Window material Quartz -
P805 – Hollow Cathode Lamp (HCL) – Beryllium
417.00$Review Product Voltage Requirements Instrument To suit all AAS (Atomic Absorption Spectroscopy Instruments) Pin Type / Connectivity Two (2) Pin ~ Standard Wavelength Primary Wavelength 234.9nm Alternative Wavelengths None Optical Window material Quartz -
P803T – Hollow Cathode Lamp (HCL) – Arsenic [Tubular]
385.00$Review Product Voltage Requirements Instrument To suit all AAS (Atomic Absorption Spectroscopy Instruments) Additional Information Photron's opto-galvanic see-through lamp has been developed for higher intensity then our Standard Range Hollow Cathode Lamps There is no requirement for an additional power supply and suits all AA instruments. Pin Type / Connectivity… -
P803 – Hollow Cathode Lamp (HCL) – Arsenic
318.00$Review Product Voltage Requirements Instrument To suit all AAS (Atomic Absorption Spectroscopy Instruments) Pin Type / Connectivity Two (2) Pin ~ Standard Wavelength Primary Wavelength 193.7nm Alternative Wavelengths 189.0 ~ 197.2nm Optical Window material Quartz -
P802 – Hollow Cathode Lamp (HCL) – Antimony
270.00$Review Product Voltage Requirements Instrument To suit all AAS (Atomic Absorption Spectroscopy Instruments) Pin Type / Connectivity Two (2) Pin ~ Standard Wavelength Primary Wavelength 217.6nm Alternative Wavelengths 206.8 ~ 217.9nm Optical Window material Quartz -
P802S-10C – Super lamp – Antimony
469.00$Review Product Voltage Requirements Instrument To suit all AAS (Atomic Absorption Spectroscopy Instruments) Pin Type / Connectivity 6 Pin / Octal Base Improvement in Detection Limit 15x times the improvement over standard Hollow Cathode Lamps Wavelength Primary Wavelength 217.6nm Optical Window material Quartz Warranty Photron's warranty information can be viewed here -
P411 – Application Source Lamp – AsPb / SeSn / TlAg / CdZn / Hg / CrCoCuFeMnNi
1,399.00$Review Product Voltage Requirements (Run Currents Datasheet) Instrument Currently this lamp is only directly usable in a GBC Scientific 932, 932plus and a Sensor Atomic Absorption Spectrometer (AAS) Pin Type / Connectivity Seven (7) Pin ~ Octal Industry Usage Metallic Alloys Wavelength Aluminium Primary Wavelength 296.2nm Alternative Wavelengths 308.2 ~… -
P409 – Application Source Lamp – Aluminium / Copper / Manganese / Lead / Tin / Zinc
899.00$Review Product Voltage Requirements (Run Currents Datasheet) Instrument Currently this lamp is only directly usable in a GBC Scientific 932, 932plus and a Sensor Atomic Absorption Spectrometer (AAS) Pin Type / Connectivity Seven (7) Pin ~ Octal Industry Usage Metallic Alloys Wavelength Aluminium Primary Wavelength 296.2nm Alternative Wavelengths 308.2 ~… -
P408 – Application Source Lamp – Aluminium / Bismuth / Manganese / Sodium /Silicon / Vanadium
899.00$Review Product Voltage Requirements (Run Currents Datasheet) Instrument Currently this lamp is only directly usable in a GBC Scientific 932, 932plus and a Sensor Atomic Absorption Spectrometer (AAS) Pin Type / Connectivity Seven (7) Pin ~ Octal Industry Usage Stainless Steel Wavelength Aluminium Primary Wavelength 396.2nm Alternative Wavelengths 308.2 ~… -
P407 – Application Source Lamp – Cobalt / Chromium / Copper / Manganese / Molybdenum / Nickel
899.00$Review Product Voltage Requirements (Run Currents Datasheet) Instrument Currently this lamp is only directly usable in a GBC Scientific 932, 932plus and a Sensor Atomic Absorption Spectrometer (AAS) Pin Type / Connectivity Seven (7) Pin ~ Octal Industry Usage Stainless Steel Wavelength Cobalt Primary Wavelength 240.7nm Alternative Wavelengths 304.4nm Chromium… -
P405 – Application Source Lamp – Calcium / Copper / Potassium / Magnesium / Sodium / Zinc
899.00$Review Product Voltage Requirements (Run Currents Datasheet) Instrument Currently this lamp is only directly usable in a GBC Scientific 932, 932plus and a Sensor Atomic Absorption Spectrometer (AAS) Pin Type / Connectivity Seven (7) Pin ~ Octal Industry Usage Clinical Alkali ~ Earths Soil & Plant Wavelength Calcium Primary Wavelength… -
P404 – Application Source Lamp – Aluminium / Copper / Iron / Magnesium / Manganese / Nickel
899.00$Review Product Voltage Requirements (Run Currents Datasheet) Instrument Currently this lamp is only directly usable in a GBC Scientific 932, 932plus and a Sensor Atomic Absorption Spectrometer (AAS) Pin Type / Connectivity Seven (7) Pin ~ Octal Industry Usage Base Metals Wavelength Aluminium Primary Wavelength 396.2nm Alternative Wavelengths 308.2 ~… -
P403 – Application Source Lamp – Arsenic / Copper / Gold / Lead / Silver / Zinc
899.00$Review Product Voltage Requirements (Run Currents Datasheet) Instrument Currently this lamp is only directly usable in a GBC Scientific 932, 932plus and a Sensor Atomic Absorption Spectrometer (AAS) Pin Type / Connectivity Seven (7) Pin ~ Octal Industry Usage Mining Wavelength Silver Primary Wavelength 328.1nm Alternative Wavelengths 338.3nm Arsenic Primary… -
P402 – Application Source Lamp – Aluminium / Iron / Nickel / Silicon / Titanium / Vanadium
899.00$Review Product Voltage Requirements (Run Currents Datasheet) Instrument Currently this lamp is only directly usable in a GBC Scientific 932, 932plus and a SenAA Atomic Absorption Spectrometer (AAS) Pin Type / Connectivity Seven (7) Pin ~ Octal Industry Usage Petrochemical Wavelength Aluminium Primary Wavelength 396.2nm Alternative Wavelengths 308.2 ~ 309.3… -
P703 – Deuterium Lamp
320.00$Download Product Datasheet Instrument Perkin Elmer/Hitachi / Merck/Hitachi / Hitachi Electrical Filament / Heater Voltage Start 10 VDC Operating 5 - 7 VDC Filament / Heater Current 1.5A Max Discharge / Arc Voltage Strike @25°C >350 VDC Operating 60 - 90 VDC Discharge / Arc Current 10 -300mA Leads Black… -
P705 – Deuterium Lamp
287.00$Download Product Datasheet Instrument Aktec / Beckman / Biorad / Joyce Loebl / Kontron LDC / Varian / Waters / Saitron / Spectra Physics / Turner Electrical Filament / Heater Voltage Start 2.5 - 3.0 VDC Operating 1.5 - 2.0 Filament / Heater Current 4.5A Max Discharge / Arc Voltage Strike… -
P858X – Astronomical Calibration Lamp – Thorium (Xenon Gas Fill)
592.90$Instrument To suit all AAS (Atomic Absorption Spectroscopy Instruments) Gas Fill Xenon - Used for Spectral Calibiration in Astronomical Industry Pin Type / Connectivity Two (2) Pin ~ Standard Wavelength Primary Wavelength 371.9nm Alternative Wavelengths None Optical Window material Quartz Warranty Photron's warranty information can be viewed here Review Product Voltage Requirements -
P809ST – Optogalvanic (See Through Hollow Cathode Lamp HCL) – Calcium
4,400.00$Optogalvanic Lamps or See Through Hollow Cathode Lamps (HCL) are designed to act as a frequency stable reference for high intensity tuneable monochromatic light sources, particularly lasers. Most of the cathode materials used in standard hollow cathode lamps may be used in the “see-through” design. We can also offer a range…