-
P702 – Deuterium Lamp
287.00$Download Product Datasheet Instrument GBC Scientific Electrical Filament / Heater Voltage Start 10 VDC Operating 5 - 7 VDC Filament / Heater Current 1.5A Max Discharge / Arc Voltage Strike @25°C >350 VDC Operating 60 - 90 VDC Discharge / Arc Current 10 -300mA Terminals Octal connector Optical Window material… -
P701 – Deuterium Lamp
256.00$Download Product Datasheet Instrument GBC Scientific Electrical Filament / Heater Voltage Start 10 VDC Operating 5 - 7 VDC Filament / Heater Current 1.5A Max Discharge / Arc Voltage Strike @25_C >350 VDC Operating 60 - 90 VDC Discharge / Arc Current 10 -300mA Leads Black Filament & Cathode Red… -
P700 – Deuterium Lamp
249.00$Download Product Datasheet Instrument Various Electrical Filament / Heater Voltage Start 10 VDC Operating 5 - 7 VDC Filament / Heater Current 1.5A Max Discharge / Arc Voltage Strike @25°C >350 VDC Operating 60 - 90 VDC Discharge / Arc Current 10 -300mA Leads Black Filament & Cathode Red Anode… -
P411 – Application Source Lamp – AsPb / SeSn / TlAg / CdZn / Hg / CrCoCuFeMnNi
1,399.00$Review Product Voltage Requirements (Run Currents Datasheet) Instrument Currently this lamp is only directly usable in a GBC Scientific 932, 932plus and a Sensor Atomic Absorption Spectrometer (AAS) Pin Type / Connectivity Seven (7) Pin ~ Octal Industry Usage Metallic Alloys Wavelength Aluminium Primary Wavelength 296.2nm Alternative Wavelengths 308.2 ~… -
P410 – Application Source Lamps – Custom Creation
1,499.00$Review Product Voltage Requirements (Run Currents Datasheet) THIS PRODUCT SHOULD BE ADDED TO YOUR SHOPPING CART! Photron's P410 series are speciality instruments and contain explicit requirements that must be approved by Photron personnel. If you wish to have your design approved please use the methods detailed below. Customers with pre-approved… -
P409 – Application Source Lamp – Aluminium / Copper / Manganese / Lead / Tin / Zinc
899.00$Review Product Voltage Requirements (Run Currents Datasheet) Instrument Currently this lamp is only directly usable in a GBC Scientific 932, 932plus and a Sensor Atomic Absorption Spectrometer (AAS) Pin Type / Connectivity Seven (7) Pin ~ Octal Industry Usage Metallic Alloys Wavelength Aluminium Primary Wavelength 296.2nm Alternative Wavelengths 308.2 ~… -
P408 – Application Source Lamp – Aluminium / Bismuth / Manganese / Sodium /Silicon / Vanadium
899.00$Review Product Voltage Requirements (Run Currents Datasheet) Instrument Currently this lamp is only directly usable in a GBC Scientific 932, 932plus and a Sensor Atomic Absorption Spectrometer (AAS) Pin Type / Connectivity Seven (7) Pin ~ Octal Industry Usage Stainless Steel Wavelength Aluminium Primary Wavelength 396.2nm Alternative Wavelengths 308.2 ~… -
P407 – Application Source Lamp – Cobalt / Chromium / Copper / Manganese / Molybdenum / Nickel
899.00$Review Product Voltage Requirements (Run Currents Datasheet) Instrument Currently this lamp is only directly usable in a GBC Scientific 932, 932plus and a Sensor Atomic Absorption Spectrometer (AAS) Pin Type / Connectivity Seven (7) Pin ~ Octal Industry Usage Stainless Steel Wavelength Cobalt Primary Wavelength 240.7nm Alternative Wavelengths 304.4nm Chromium… -
P406 – Application Source Lamp – Chromium / Copper / Iron / Nickel / Lead / Zinc
899.00$Instrument Currently this lamp is only directly usable in a GBC Scientific 932, 932plus and a Sensor Atomic Absorption Spectrometer (AAS) Pin Type / Connectivity Seven (7) Pin ~ Octal Industry Usage Base Metals Wavelength Chromium Primary Wavelength 357.9nm Alternative Wavelengths 425.4 ~ 427.5nm Copper Primary Wavelength 324.8nm Alternative Wavelengths… -
P405 – Application Source Lamp – Calcium / Copper / Potassium / Magnesium / Sodium / Zinc
899.00$Review Product Voltage Requirements (Run Currents Datasheet) Instrument Currently this lamp is only directly usable in a GBC Scientific 932, 932plus and a Sensor Atomic Absorption Spectrometer (AAS) Pin Type / Connectivity Seven (7) Pin ~ Octal Industry Usage Clinical Alkali ~ Earths Soil & Plant Wavelength Calcium Primary Wavelength… -
P404 – Application Source Lamp – Aluminium / Copper / Iron / Magnesium / Manganese / Nickel
899.00$Review Product Voltage Requirements (Run Currents Datasheet) Instrument Currently this lamp is only directly usable in a GBC Scientific 932, 932plus and a Sensor Atomic Absorption Spectrometer (AAS) Pin Type / Connectivity Seven (7) Pin ~ Octal Industry Usage Base Metals Wavelength Aluminium Primary Wavelength 396.2nm Alternative Wavelengths 308.2 ~… -
P403 – Application Source Lamp – Arsenic / Copper / Gold / Lead / Silver / Zinc
899.00$Review Product Voltage Requirements (Run Currents Datasheet) Instrument Currently this lamp is only directly usable in a GBC Scientific 932, 932plus and a Sensor Atomic Absorption Spectrometer (AAS) Pin Type / Connectivity Seven (7) Pin ~ Octal Industry Usage Mining Wavelength Silver Primary Wavelength 328.1nm Alternative Wavelengths 338.3nm Arsenic Primary… -
P402 – Application Source Lamp – Aluminium / Iron / Nickel / Silicon / Titanium / Vanadium
899.00$Review Product Voltage Requirements (Run Currents Datasheet) Instrument Currently this lamp is only directly usable in a GBC Scientific 932, 932plus and a SenAA Atomic Absorption Spectrometer (AAS) Pin Type / Connectivity Seven (7) Pin ~ Octal Industry Usage Petrochemical Wavelength Aluminium Primary Wavelength 396.2nm Alternative Wavelengths 308.2 ~ 309.3… -
P401 – Application Source Lamp – Arsenic / Cadmium / Mercury / Lead / Selenium / Thallium
899.00$Review Product Voltage Requirements (Run Currents Datasheet) Instrument Currently this lamp is only directly usable in a GBC Scientific 932, 932plus and a Sensor Atomic Absorption Spectrometer (AAS) Pin Type / Connectivity Seven (7) Pin ~ Octal Industry Usage Environmental ~ Food & Beverage ~ Clinical Trace Toxics Wavelength Arsenic… -
P802S – Super Lamp – Antimony
469.00$Review Product Voltage Requirements Instrument To suit all AAS (Atomic Absorption Spectroscopy Instruments) Pin Type / Connectivity 4 Pin / Octal Base Improvement in Detection Limit 15x times the improvement over standard Hollow Cathode Lamps Wavelength Primary Wavelength 217.6nm Optical Window material Quartz Warranty Photron's warranty information can be viewed here -
P802S-10C – Super lamp – Antimony
469.00$Review Product Voltage Requirements Instrument To suit all AAS (Atomic Absorption Spectroscopy Instruments) Pin Type / Connectivity 6 Pin / Octal Base Improvement in Detection Limit 15x times the improvement over standard Hollow Cathode Lamps Wavelength Primary Wavelength 217.6nm Optical Window material Quartz Warranty Photron's warranty information can be viewed here -
P802 – Hollow Cathode Lamp (HCL) – Antimony
270.00$Review Product Voltage Requirements Instrument To suit all AAS (Atomic Absorption Spectroscopy Instruments) Pin Type / Connectivity Two (2) Pin ~ Standard Wavelength Primary Wavelength 217.6nm Alternative Wavelengths 206.8 ~ 217.9nm Optical Window material Quartz -
P801 – Hollow Cathode Lamp (HCL) – Aluminium
240.00$Review Product Voltage Requirements Instrument To suit all AAS (Atomic Absorption Spectroscopy Instruments) Pin Type / Connectivity Two (2) Pin ~ Standard Wavelength Primary Wavelength 396.2nm Alternative Wavelengths 308.2 ~ 309.3 Optical Window material Quartz -
P803 – Hollow Cathode Lamp (HCL) – Arsenic
318.00$Review Product Voltage Requirements Instrument To suit all AAS (Atomic Absorption Spectroscopy Instruments) Pin Type / Connectivity Two (2) Pin ~ Standard Wavelength Primary Wavelength 193.7nm Alternative Wavelengths 189.0 ~ 197.2nm Optical Window material Quartz -
P803T – Hollow Cathode Lamp (HCL) – Arsenic [Tubular]
385.00$Review Product Voltage Requirements Instrument To suit all AAS (Atomic Absorption Spectroscopy Instruments) Additional Information Photron's opto-galvanic see-through lamp has been developed for higher intensity then our Standard Range Hollow Cathode Lamps There is no requirement for an additional power supply and suits all AA instruments. Pin Type / Connectivity… -
P805 – Hollow Cathode Lamp (HCL) – Beryllium
417.00$Review Product Voltage Requirements Instrument To suit all AAS (Atomic Absorption Spectroscopy Instruments) Pin Type / Connectivity Two (2) Pin ~ Standard Wavelength Primary Wavelength 234.9nm Alternative Wavelengths None Optical Window material Quartz -
P806 – Hollow Cathode Lamp (HCL) – Bismuth
272.00$Review Product Voltage Requirements Instrument To suit all AAS (Atomic Absorption Spectroscopy Instruments) Pin Type / Connectivity Two (2) Pin ~ Standard Wavelength Primary Wavelength 223.1nm Alternative Wavelengths 22.8 ~ 227.7nm Optical Window material Quartz -
P807 – Hollow Cathode Lamp (HCL) – Boron
272.00$Review Product Voltage Requirements Instrument To suit all AAS (Atomic Absorption Spectroscopy Instruments) Pin Type / Connectivity Two (2) Pin ~ Standard Wavelength Primary Wavelength 24.8nm Alternative Wavelengths 208.9nm Optical Window material Quartz
















































