P941 – Hollow Cathode Lamp (HCL) to suit Perkin Elmer – Potassium
279.00$Instrument Perkin Elmer Atomic Absorption Spectrometer (AAS) Pin Type / Connectivity Nine (9) Pin ~ Standard Wavelength Primary Wavelength 766.5nm Alternative Wavelengths 404.4 ~ 769.9nm Optical Window material Quartz -
P952 – Hollow Cathode Lamp (HCL) to suit Perkin Elmer – Sodium
279.00$Instrument Perkin Elmer Atomic Absorption Spectrometer (AAS) Pin Type / Connectivity Nine (9) Pin ~ Standard Wavelength Primary Wavelength 589.0nm Alternative Wavelengths 330.2 ~ 589.6nm Optical Window material Quartz -
P961 – Hollow Cathode Lamp (HCL) to suit Perkin Elmer – Titanium
279.00$Instrument Perkin Elmer Atomic Absorption Spectrometer (AAS) Pin Type / Connectivity Nine (9) Pin ~ Standard Wavelength Primary Wavelength 364.3nm Alternative Wavelengths 365.4 ~ 399.0nm Optical Window material Quartz -
P801UC – Hollow Cathode Lamp (HCL) – Thermo Fisher / Unicam – Aluminium
280.00$Review Product Voltage Requirements Instrument To suit Thermo / Unicam Pin Type / Connectivity Seven (7) Pin ~ Coded Wavelength Primary Wavelength 396.2nm Alternative Wavelengths 308.2 ~ 309.3 Optical Window material Quartz Warranty Photron's warranty information can be viewed here -
P814UC- Hollow Cathode Lamp (HCL)- Thermo Fisher / Unicam – Copper
280.00$Review Product Voltage Requirements Instrument To suit Thermo / Unicam Pin Type / Connectivity Seven (7) Pin ~ Coded Wavelength Primary Wavelength 324.8nm Alternative Wavelengths 217.9nm ~ 218.2nm Optical Window material Quartz -
P826UC – Hollow Cathode Lamp (HCL) – Thermo Fisher / Unicam – Iron
280.00$Review Product Voltage Requirements Instrument To suit Thermo / Unicam Pin Type / Connectivity Seven (7) Pin ~ Coded Wavelength Primary Wavelength 248.3nm Alternative Wavelengths 248.8 ~ 372.0nm Optical Window material Quartz -
P828C – Hollow Cathode Lamp (HCL) – Agilent Coded – Lead
282.00$Instrument To suit Varian / GBC Scientific Pin Type / Connectivity Four (4) Pin ~ Coded Wavelength Primary Wavelength 217.0nm Alternative Wavelengths 283.3 ~ 261.4nm Optical Window material Quartz -
P867C – Hollow Cathode Lamp (HCL) – Agilent Coded – Zinc
282.00$Review Product Voltage Requirements Instrument To suit Varian / GBC Pin Type / Connectivity Four (4) Pin ~ Coded Wavelength Primary Wavelength 213.9nm Alternative Wavelengths 307.6nm Optical Window material Quartz -
P862 – Hollow Cathode Lamp (HCL) – Tungsten
284.00$Review Product Voltage Requirements Instrument To suit all AAS (Atomic Absorption Spectroscopy Instruments) Pin Type / Connectivity Two (2) Pin ~ Standard Wavelength Primary Wavelength 255.1nm Alternative Wavelengths 294.7 ~ 400.9nm Optical Window material Quartz -
P854 – Hollow Cathode Lamp (HCL) – Tantalum
285.00$Review Product Voltage Requirements Instrument To suit all AAS (Atomic Absorption Spectroscopy Instruments) Pin Type / Connectivity Two (2) Pin ~ Standard Wavelength Primary Wavelength 271.5nm Alternative Wavelengths 275.8nm Optical Window material Quartz -
P861C – Hollow Cathode Lamp (HCL) – Agilent Coded – Titanium
286.00$Instrument To suit Varian / GBC Scientific Pin Type / Connectivity Four (4) Pin ~ Coded Wavelength Primary Wavelength 364.3nm Alternative Wavelengths 365.4 ~ 399.0nm Optical Window material Quartz -
P705 – Deuterium Lamp
287.00$Download Product Datasheet Instrument Aktec / Beckman / Biorad / Joyce Loebl / Kontron LDC / Varian / Waters / Saitron / Spectra Physics / Turner Electrical Filament / Heater Voltage Start 2.5 - 3.0 VDC Operating 1.5 - 2.0 Filament / Heater Current 4.5A Max Discharge / Arc Voltage Strike… -
P702 – Deuterium Lamp
287.00$Download Product Datasheet Instrument GBC Scientific Electrical Filament / Heater Voltage Start 10 VDC Operating 5 - 7 VDC Filament / Heater Current 1.5A Max Discharge / Arc Voltage Strike @25°C >350 VDC Operating 60 - 90 VDC Discharge / Arc Current 10 -300mA Terminals Octal connector Optical Window material… -
P704 – Deuterium Lamp
287.00$Download Product Datasheet Instrument Altec / Beckman / Biorad / Dupont / Erma Hitachi / Jasco / Unicam / Varian Electrical Filament / Heater Voltage Start 10 VDC Operating 5 - 7 VDC Filament / Heater Current 1.5A Max Discharge / Arc Voltage Strike @25°C >350 VDC Operating 60 -… -
P850UC – Hollow Cathode Lamp (HCL) – Thermo Fisher / Unicam – Silicon
287.00$Review Product Voltage Requirements Instrument To suit Thermo / Unicam Pin Type / Connectivity Seven (7) Pin ~ Coded Wavelength Primary Wavelength 251.6nm Alternative Wavelengths 250.7 ~ 251.4nm Optical Window material Quartz -
P851UC – Hollow Cathode Lamp (HCL) – Thermo Fisher / Unicam – Silver
287.00$Review Product Voltage Requirements Instrument To suit Thermo / Unicam Pin Type / Connectivity Seven (7) Pin ~ Coded Wavelength Primary Wavelength 328.1nm Alternative Wavelengths 338.3nm Optical Window material Quartz -
P852UC – Hollow Cathode Lamp (HCL) – Thermo Fisher / Unicam – Sodium
287.00$Review Product Voltage Requirements Instrument To suit Thermo / Unicam Pin Type / Connectivity Seven (7) Pin ~ Coded Wavelength Primary Wavelength 589.0nm Alternative Wavelengths 330.2 ~ 589.6nm Optical Window material Quartz -
P706 – Deuterium Lamp
287.00$Download Product Datasheet Instrument Varian Electrical Filament / Heater Voltage Start 10 VDC Operating 5 - 7 VDC Filament / Heater Current 1.5A Max Discharge / Arc Voltage Strike @25°C >350 VDC Operating 60 - 90 VDC Discharge / Arc Current 10 -300mA Leads Black Filament & Cathode Red Anode… -
P714 – Deuterium Lamp
287.00$Download Product Datasheet Instrument Spectra Physics Electrical Filament / Heater Voltage Start 2.5 - 3.0 VDC Operating 1.5 - 2.0 Filament / Heater Current 4.5A Max Discharge / Arc Voltage Strike @25°C >350 VDC Operating 60 - 90 VDC Discharge / Arc Current 10 -300mA Leads Black Filament & Cathode… -
P715 – Deuterium Lamp
287.00$Download Product Datasheet Instrument Varian Electrical Filament / Heater Voltage Start 10 VDC Operating 5 - 7 VDC Filament / Heater Current 1.5A Max Discharge / Arc Voltage Strike @25°C >350 VDC Operating 60 - 90 VDC Discharge / Arc Current 10 -300mA Leads Black Filament & Cathode Red Anode… -
P718 – Deuterium Lamp
287.00$Download Product Datasheet Instrument Perkin Elmer Electrical Filament / Heater Voltage Start 10 VDC Operating 5 - 7 VDC Filament / Heater Current 1.5A Max Discharge / Arc Voltage Strike @25°C >350 VDC Operating 60 - 90 VDC Discharge / Arc Current 10 -300mA Leads Black Filament & Cathode Red… -
P726 – Deuterium Lamp
287.00$Download Product Datasheet Instrument Jasco 7800 Electrical Filament / Heater Voltage Start 2.5 - 3.0 VDC Operating 1.5 - 2.0 Filament / Heater Current 4.5A Max Discharge / Arc Voltage Strike @25°C >350 VDC Operating 60 - 90 VDC Discharge / Arc Current 10 -300mA Terminals Octal Connector Optical Window… -
P831C – Hollow Cathode Lamp (HCL) – Agilent Coded – Magnesium
289.00$Instrument To suit Varian / GBC Scientific Pin Type / Connectivity Four (4) Pin ~ Coded Wavelength Primary Wavelength 285.2nm Alternative Wavelengths 202.5nm Optical Window material Quartz -
P829C – Hollow Cathode Lamp (HCL) – Agilent Coded – Lithium
290.00$Instrument To suit Varian / GBC Scientific Pin Type / Connectivity Four (4) Pin ~ Coded Wavelength Primary Wavelength 670.8nm Alternative Wavelengths 323.3nm Optical Window material Quartz -
P860C – Hollow Cathode Lamp (HCL) – Agilent Coded – Tin
290.00$Instrument To suit Varian / GBC Scientific Pin Type / Connectivity Four (4) Pin ~ Coded Wavelength Primary Wavelength 235.5nm Alternative Wavelengths 224.6 ~ 266.1nm Optical Window material Quartz -
P828UC – Hollow Cathode Lamp (HCL) – Thermo Fisher / Unicam – Lead
292.00$Review Product Voltage Requirements Instrument To suit Thermo / Unicam Pin Type / Connectivity Seven (7) Pin ~ Coded Wavelength Primary Wavelength 217.0nm Alternative Wavelengths 283.3 ~ 261.4nm Optical Window material Quartz -
P867UC – Hollow Cathode Lamp (HCL) – Thermo Fisher / Unicam – Zinc
292.00$Review Product Voltage Requirements Instrument To suit Thermo / Unicam Pin Type / Connectivity Seven (7) Pin ~ Coded Wavelength Primary Wavelength 213.9nm Alternative Wavelengths 307.6nm Optical Window material Quartz -
P861UC – Hollow Cathode Lamp (HCL) – Thermo Fisher / Unicam – Titanium
296.00$Review Product Voltage Requirements Instrument To suit Thermo / Unicam Pin Type / Connectivity Seven (7) Pin ~ Coded Wavelength Primary Wavelength 364.3nm Alternative Wavelengths 365.4 ~ 399.0nm Optical Window material Quartz -
P802C – Hollow Cathode Lamp (HCL) – Agilent Coded – Antimony
299.00$Instrument To suit Varian / GBC Scientific Pin Type / Connectivity Four (4) Pin ~ Coded Wavelength Primary Wavelength 217.6nm Alternative Wavelengths 206.8 ~ 217.9nm Optical Window material Quartz -
P836UC- Hollow Cathode Lamp (HCL) – Thermo Fisher / Unicam – Nickel
299.00$Instrument To suit Thermo / Unicam Pin Type / Connectivity Seven (7) Pin ~ Coded Wavelength Primary Wavelength 232.0nm Alternative Wavelengths 231.1 ~ 341.5nm Optical Window material Quartz -
P859 – Hollow Cathode Lamp (HCL) – Thulium
299.00$Review Product Voltage Requirements Instrument To suit all AAS (Atomic Absorption Spectroscopy Instruments) Pin Type / Connectivity Two (2) Pin ~ Standard Wavelength Primary Wavelength 371.8nm Alternative Wavelengths 436.0 ~ 410.6nm Optical Window material Quartz -
P864 – Hollow Cathode Lamp (HCL) – Vanadium
299.00$Review Product Voltage Requirements Instrument To suit all AAS (Atomic Absorption Spectroscopy Instruments) Pin Type / Connectivity Two (2) Pin ~ Standard Wavelength Primary Wavelength 318.5nm Alternative Wavelengths 306.6 ~ 318.4nm Optical Window material Quartz -
P872 – Hollow Cathode Lamp (HCL) – Copper / Zinc
299.00$Review Product Voltage Requirements Instrument To suit all AAS (Atomic Absorption Spectroscopy Instruments) Pin Type / Connectivity Two (2) Pin ~ Standard Wavelength Primary Wavelength Alternative Wavelengths Optical Window material Quartz -
P806C – Hollow Cathode Lamp (HCL) – Agilent Coded – Bismuth
299.00$Instrument To suit Varian / GBC Scientific Pin Type / Connectivity Four (4) Pin ~ Coded Wavelength Primary Wavelength 223.1nm Alternative Wavelengths 22.8 ~ 227.7nm Optical Window material Quartz -
P812C – Hollow Cathode Lamp (HCL) – Agilent Coded – Chromium
299.00$Instrument To suit Varian / GBC Scientific Pin Type / Connectivity Four (4) Pin ~ Coded Wavelength Primary Wavelength 357.9nm Alternative Wavelengths 425.4 ~ 427.5nm Optical Window material Quartz -
P802UC- Hollow Cathode Lamp (HCL)- Thermo Fisher / Unicam – Antimony
299.00$Review Product Voltage Requirements Instrument To suit Thermo / Unicam Pin Type / Connectivity Seven (7) Pin ~ Coded Wavelength Primary Wavelength 217.6nm Alternative Wavelengths 206.8 ~ 217.9nm Optical Window material Quartz -
P806UC- Hollow Cathode Lamp (HCL)- Thermo Fisher / Unicam – Bismuth
299.00$Review Product Voltage Requirements Instrument To suit Thermo / Unicam Pin Type / Connectivity Seven (7) Pin ~ Coded Wavelength Primary Wavelength 223.1nm Alternative Wavelengths 22.8 ~ 227.7nm Optical Window material Quartz -
P807UC – Hollow Cathode Lamp (HCL) – Thermo Fisher / Unicam – Boron
299.00$Review Product Voltage Requirements Instrument To suit Thermo / Unicam Pin Type / Connectivity Seven (7) Pin ~ Coded Wavelength Primary Wavelength 24.8nm Alternative Wavelengths 208.9nm Optical Window material Quartz -
P808UC – Hollow Cathode Lamp (HCL) – Thermo Fisher / Unicam – Cadmium
299.00$Instrument To suit Thermo / Unicam Pin Type / Connectivity Seven (7) Pin ~ Coded Wavelength Primary Wavelength 228.8nm Alternative Wavelengths 326.1nm Optical Window material Quartz -
P809UC – Hollow Cathode Lamp (HCL) – Thermo Fisher / Unicam – Calcium
299.00$Review Product Voltage Requirements Instrument To suit Thermo / Unicam Pin Type / Connectivity Seven (7) Pin ~ Coded Wavelength Primary Wavelength 422.7nm Alternative Wavelengths 239.9nm Optical Window material Quartz -
P812UC- Hollow Cathode Lamp (HCL)- Thermo Fisher / Unicam – Chromium
299.00$Review Product Voltage Requirements Instrument To suit Thermo / Unicam Pin Type / Connectivity Seven (7) Pin ~ Coded Wavelength Primary Wavelength 357.9nm Alternative Wavelengths 425.4 ~ 427.5nm Optical Window material Quartz -
P813UC – Hollow Cathode Lamp (HCL) – Thermo Fisher / Unicam – Cobalt
299.00$Review Product Voltage Requirements Instrument To suit Thermo / Unicam Pin Type / Connectivity Seven (7) Pin ~ Coded Wavelength Primary Wavelength 240.7nm Alternative Wavelengths 304.4nm Optical Window material Quartz -
P831UC – Hollow Cathode Lamp (HCL) – Thermo Fisher / Unicam – Magnesium
299.00$Review Product Voltage Requirements Instrument To suit Thermo / Unicam Pin Type / Connectivity Seven (7) Pin ~ Coded Wavelength Primary Wavelength 285.2nm Alternative Wavelengths 202.5nm Optical Window material Quartz -
P832UC- Hollow Cathode Lamp (HCL) – Thermo Fisher / Unicam – Manganese
299.00$Review Product Voltage Requirements Instrument To suit Thermo / Unicam Pin Type / Connectivity Seven (7) Pin ~ Coded Wavelength Primary Wavelength 279.5nm Alternative Wavelengths 279.8 ~ 280.1nm Optical Window material Quartz -
P833UC – Hollow Cathode Lamp (HCL) – Thermo Fisher / Unicam – Mercury
299.00$Review Product Voltage Requirements Instrument To suit Thermo / Unicam Pin Type / Connectivity Seven (7) Pin ~ Coded Wavelength Primary Wavelength 253.7nm Alternative Wavelengths None Optical Window material Quartz