P932LL – Hollow Cathode Lamp (HCL) to suit Cableless Perkin Elmer – Manganese
429.00$Instrument Perkin Elmer Atomic Absorption Spectroscopy (AAnalyst Series of Instruments) Pin Type / Connectivity Four (4) Pin ~ Cableless Notes This lamp also features EPROM for digital coding Wavelength Primary Wavelength 279.5nm Alternative Wavelengths 279.8 ~ 280.1nm Optical Window material Quartz -
P933 – Hollow Cathode Lamp (HCL) to suit Perkin Elmer – Mercury
299.00$Instrument Perkin Elmer Atomic Absorption Spectrometer (AAS) Pin Type / Connectivity Nine (9) Pin ~ Standard Wavelength Primary Wavelength 253.7nm Alternative Wavelengths None Optical Window material Quartz -
P933C – Hollow Cathode Lamp (HCL) to suit Coded Perkin Elmer – Mercury
328.90$Instrument Perkin Elmer Atomic Absorption Spectrocopy Pin Type / Connectivity Twelve (12) Pin ~ Coded Wavelength Primary Wavelength 253.7nm Alternative Wavelengths None Optical Window material Quartz -
P933LL – Hollow Cathode Lamp (HCL) to suit Cableless Perkin Elmer – Mercury
464.00$Instrument Perkin Elmer Atomic Absorption Spectroscopy (AAnalyst Series of Instruments) Pin Type / Connectivity Four (4) Pin ~ Cableless Notes This lamp also features EPROM for digital coding Wavelength Primary Wavelength 253.7nm Alternative Wavelengths None Optical Window material Quartz -
P934 – Hollow Cathode Lamp (HCL) to suit Perkin Elmer – Molybdenum
299.00$Instrument Perkin Elmer Atomic Absorption Spectrometer (AAS) Pin Type / Connectivity Nine (9) Pin ~ Standard Wavelength Primary Wavelength 313.3nm Alternative Wavelengths 320.9nm Optical Window material Quartz -
P934C – Hollow Cathode Lamp (HCL) to suit Coded Perkin Elmer – Molybdenum
328.90$Instrument Perkin Elmer Atomic Absorption Spectrocopy Pin Type / Connectivity Twelve (12) Pin ~ Coded Wavelength Primary Wavelength 313.3nm Alternative Wavelengths 320.9nm Optical Window material Quartz -
P934LL – Hollow Cathode Lamp (HCL) to suit Cableless Perkin Elmer – Molybdenum
429.00$Instrument Perkin Elmer Atomic Absorption Spectroscopy (AAnalyst Series of Instruments) Pin Type / Connectivity Four (4) Pin ~ Cableless Notes This lamp also features EPROM for digital coding Wavelength Primary Wavelength 313.3nm Alternative Wavelengths 320.9nm Optical Window material Quartz -
P935 – Hollow Cathode Lamp (HCL) to suit Perkin Elmer – Neodymium
299.00$Instrument Perkin Elmer Atomic Absorption Spectrometer (AAS) Pin Type / Connectivity Nine (9) Pin ~ Standard Wavelength Primary Wavelength 492.5nm Alternative Wavelengths 463.4nm Optical Window material Quartz -
P935C – Hollow Cathode Lamp (HCL) to suit Coded Perkin Elmer – Neodymium
328.90$Instrument Perkin Elmer Atomic Absorption Spectrocopy Pin Type / Connectivity Twelve (12) Pin ~ Coded Wavelength Primary Wavelength 492.5nm Alternative Wavelengths 463.4nm Optical Window material Quartz -
P935LL – Hollow Cathode Lamp (HCL) to suit Cableless Perkin Elmer – Neodymium
499.00$Instrument Perkin Elmer Atomic Absorption Spectroscopy (AAnalyst Series of Instruments) Pin Type / Connectivity Four (4) Pin ~ Cableless Notes This lamp also features EPROM for digital coding Wavelength Primary Wavelength 492.5nm Alternative Wavelengths 463.4nm Optical Window material Quartz -
P936 – Hollow Cathode Lamp (HCL) to suit Perkin Elmer – Nickel
299.00$Instrument Perkin Elmer Atomic Absorption Spectrometer (AAS) Pin Type / Connectivity Nine (9) Pin ~ Standard Wavelength Primary Wavelength 232.0nm Alternative Wavelengths 231.1 ~ 341.5nm Optical Window material Quartz -
P936C – Hollow Cathode Lamp (HCL) to suit Coded Perkin Elmer – Nickel
328.90$Instrument Perkin Elmer Atomic Absorption Spectrocopy Pin Type / Connectivity Twelve (12) Pin ~ Coded Wavelength Primary Wavelength 232.0nm Alternative Wavelengths 231.1 ~ 341.5nm Optical Window material Quartz -
P936LL – Hollow Cathode Lamp (HCL) to suit Cableless Perkin Elmer – Nickel
429.00$Instrument Perkin Elmer Atomic Absorption Spectroscopy (AAnalyst Series of Instruments) Pin Type / Connectivity Four (4) Pin ~ Cableless Notes This lamp also features EPROM for digital coding Wavelength Primary Wavelength 232.0nm Alternative Wavelengths 231.1 ~ 341.5nm Optical Window material Quartz -
P937 – Hollow Cathode Lamp (HCL) to suit Perkin Elmer – Niobium
397.00$Instrument Perkin Elmer Atomic Absorption Spectrometer (AAS) Pin Type / Connectivity Nine (9) Pin ~ Standard Wavelength Primary Wavelength 334.9nm Alternative Wavelengths 405.9 ~ 408.0nm Optical Window material Quartz -
P937C – Hollow Cathode Lamp (HCL) to suit Coded Perkin Elmer – Niobium
436.70$Instrument Perkin Elmer Atomic Absorption Spectrocopy Pin Type / Connectivity Twelve (12) Pin ~ Coded Wavelength Primary Wavelength 334.9nm Alternative Wavelengths 405.9 ~ 408.0nm Optical Window material Quartz -
P937LL – Hollow Cathode Lamp (HCL) to suit Cableless Perkin Elmer – Niobium
499.00$Instrument Perkin Elmer Atomic Absorption Spectroscopy (AAnalyst Series of Instruments) Pin Type / Connectivity Four (4) Pin ~ Cableless Notes This lamp also features EPROM for digital coding Wavelength Primary Wavelength 334.9nm Alternative Wavelengths 405.9 ~ 408.0nm Optical Window material Quartz -
P938 – Hollow Cathode Lamp (HCL) to suit Perkin Elmer – Osmium
499.00$Instrument Perkin Elmer Atomic Absorption Spectrometer (AAS) Pin Type / Connectivity Nine (9) Pin ~ Standard Wavelength Primary Wavelength 290.9nm Alternative Wavelengths 305.9 ~ 426.0nm Optical Window material Quartz -
P939 – Hollow Cathode Lamp (HCL) to suit Perkin Elmer – Palladium
499.00$Instrument Perkin Elmer Atomic Absorption Spectrometer (AAS) Pin Type / Connectivity Nine (9) Pin ~ Standard Wavelength Primary Wavelength 247.6nm Alternative Wavelengths 244.8 ~ 340.5nm Optical Window material Quartz -
P939C – Hollow Cathode Lamp (HCL) to suit Coded Perkin Elmer – Palladium
548.90$Instrument Perkin Elmer Atomic Absorption Spectrocopy Pin Type / Connectivity Twelve (12) Pin ~ Coded Wavelength Primary Wavelength 247.6nm Alternative Wavelengths 244.8 ~ 340.5nm Optical Window material Quartz -
P939LL – Hollow Cathode Lamp (HCL) to suit Cableless Perkin Elmer – Palladium
529.00$Instrument Perkin Elmer Atomic Absorption Spectroscopy (AAnalyst Series of Instruments) Pin Type / Connectivity Four (4) Pin ~ Cableless Notes This lamp also features EPROM for digital coding Wavelength Primary Wavelength 247.6nm Alternative Wavelengths 244.8 ~ 340.5nm Optical Window material Quartz -
P940 – Hollow Cathode Lamp (HCL) to suit Perkin Elmer – Platinum
399.00$Instrument Perkin Elmer Atomic Absorption Spectrometer (AAS) Pin Type / Connectivity Nine (9) Pin ~ Standard Wavelength Primary Wavelength 265.9nm Alternative Wavelengths 264.7 ~ 299.8nm Optical Window material Quartz -
P940LL – Hollow Cathode Lamp (HCL) to suit Cableless Perkin Elmer – Platinum
499.00$Instrument Perkin Elmer Atomic Absorption Spectroscopy (AAnalyst Series of Instruments) Pin Type / Connectivity Four (4) Pin ~ Cableless Notes This lamp also features EPROM for digital coding Wavelength Primary Wavelength 265.9nm Alternative Wavelengths 264.7 ~ 299.8nm Optical Window material Quartz -
P941 – Hollow Cathode Lamp (HCL) to suit Perkin Elmer – Potassium
279.00$Instrument Perkin Elmer Atomic Absorption Spectrometer (AAS) Pin Type / Connectivity Nine (9) Pin ~ Standard Wavelength Primary Wavelength 766.5nm Alternative Wavelengths 404.4 ~ 769.9nm Optical Window material Quartz -
P941C – Hollow Cathode Lamp (HCL) to suit Coded Perkin Elmer – Potassium
306.90$Instrument Perkin Elmer Atomic Absorption Spectrocopy Pin Type / Connectivity Twelve (12) Pin ~ Coded Wavelength Primary Wavelength 766.5nm Alternative Wavelengths 404.4 ~ 769.9nm Optical Window material Quartz -
P941LL – Hollow Cathode Lamp (HCL) to suit Cableless Perkin Elmer – Potassium
364.00$Instrument Perkin Elmer Atomic Absorption Spectroscopy (AAnalyst Series of Instruments) Pin Type / Connectivity Four (4) Pin ~ Cableless Notes This lamp also features EPROM for digital coding Wavelength Primary Wavelength 766.5nm Alternative Wavelengths 404.4 ~ 769.9nm Optical Window material Quartz -
P942 – Hollow Cathode Lamp (HCL) to suit Perkin Elmer – Praseodymium
399.00$Instrument Perkin Elmer Atomic Absorption Spectrometer (AAS) Pin Type / Connectivity Nine (9) Pin ~ Standard Wavelength Primary Wavelength 495.1nm Alternative Wavelengths 513.3nm Optical Window material Quartz -
P942C – Hollow Cathode Lamp (HCL) to suit Coded Perkin Elmer – Praseodymium
438.90$Instrument Perkin Elmer Atomic Absorption Spectrocopy Pin Type / Connectivity Twelve (12) Pin ~ Coded Wavelength Primary Wavelength 495.1nm Alternative Wavelengths 513.3nm Optical Window material Quartz -
P942LL – Hollow Cathode Lamp (HCL) to suit Cableless Perkin Elmer – Praseodymium
469.00$Instrument Perkin Elmer Atomic Absorption Spectroscopy (AAnalyst Series of Instruments) Pin Type / Connectivity Four (4) Pin ~ Cableless Notes This lamp also features EPROM for digital coding Wavelength Primary Wavelength 495.1nm Alternative Wavelengths 513.3nm Optical Window material Quartz -
P943 – Hollow Cathode Lamp (HCL) to suit Perkin Elmer – Rhenium
499.00$Instrument Perkin Elmer Atomic Absorption Spectrometer (AAS) Pin Type / Connectivity Nine (9) Pin ~ Standard Wavelength Primary Wavelength 346.0nm Alternative Wavelengths 346.5nm Optical Window material Quartz -
P943C – Hollow Cathode Lamp (HCL) to suit Coded Perkin Elmer – Rhenium
548.90$Instrument Perkin Elmer Atomic Absorption Spectrocopy Pin Type / Connectivity Twelve (12) Pin ~ Coded Wavelength Primary Wavelength 346.0nm Alternative Wavelengths 346.5nm Optical Window material Quartz -
P943LL – Hollow Cathode Lamp (HCL) to suit Cableless Perkin Elmer – Rhenium
524.00$Instrument Perkin Elmer Atomic Absorption Spectroscopy (AAnalyst Series of Instruments) Pin Type / Connectivity Four (4) Pin ~ Cableless Notes This lamp also features EPROM for digital coding Wavelength Primary Wavelength 346.0nm Alternative Wavelengths 346.5nm Optical Window material Quartz -
P944 – Hollow Cathode Lamp (HCL) to suit Perkin Elmer – Rhodium
699.00$Instrument Perkin Elmer Atomic Absorption Spectrometer (AAS) Pin Type / Connectivity Nine (9) Pin ~ Standard Wavelength Primary Wavelength 343.5m, Alternative Wavelengths 328.1 ~ 369.2nm Optical Window material Quartz -
P944C – Hollow Cathode Lamp (HCL) to suit Coded Perkin Elmer – Rhodium
768.90$Instrument Perkin Elmer Atomic Absorption Spectrocopy Pin Type / Connectivity Twelve (12) Pin ~ Coded Wavelength Primary Wavelength 343.5m, Alternative Wavelengths 328.1 ~ 369.2nm Optical Window material Quartz -
P944LL – Hollow Cathode Lamp (HCL) to suit Cableless Perkin Elmer – Rhodium
699.00$Instrument Perkin Elmer Atomic Absorption Spectroscopy (AAnalyst Series of Instruments) Pin Type / Connectivity Four (4) Pin ~ Cableless Notes This lamp also features EPROM for digital coding Wavelength Primary Wavelength 343.5m, Alternative Wavelengths 328.1 ~ 369.2nm Optical Window material Quartz -
P945 – Hollow Cathode Lamp (HCL) to suit Perkin Elmer – Rubidium
299.00$Instrument Perkin Elmer Atomic Absorption Spectrometer (AAS) Pin Type / Connectivity Nine (9) Pin ~ Standard Wavelength Primary Wavelength 349.9nm Alternative Wavelengths 392.6nm Optical Window material Quartz -
P946 – Hollow Cathode Lamp (HCL) to suit Perkin Elmer – Ruthenium
399.00$Instrument Perkin Elmer Atomic Absorption Spectrometer (AAS) Pin Type / Connectivity Nine (9) Pin ~ Standard Wavelength Primary Wavelength 349.9nm Alternative Wavelengths 392.6nm Optical Window material Quartz -
P946C – Hollow Cathode Lamp (HCL) to suit Coded Perkin Elmer – Ruthenium
438.90$Instrument Perkin Elmer Atomic Absorption Spectrocopy Pin Type / Connectivity Twelve (12) Pin ~ Coded Wavelength Primary Wavelength 349.9nm Alternative Wavelengths 392.6nm Optical Window material Quartz -
P946LL – Hollow Cathode Lamp (HCL) to suit Cableless Perkin Elmer – Ruthenium
529.00$Instrument Perkin Elmer Atomic Absorption Spectroscopy (AAnalyst Series of Instruments) Pin Type / Connectivity Four (4) Pin ~ Cableless Notes This lamp also features EPROM for digital coding Wavelength Primary Wavelength 349.9nm Alternative Wavelengths 392.6nm Optical Window material Quartz -
P947 – Hollow Cathode Lamp (HCL) to suit Perkin Elmer – Samarium
328.90$Instrument Perkin Elmer Atomic Absorption Spectrometer (AAS) Pin Type / Connectivity Nine (9) Pin ~ Standard Wavelength Primary Wavelength 429.7nm Alternative Wavelengths 476.0nm Optical Window material Quartz -
P947C – Hollow Cathode Lamp (HCL) to suit Coded Perkin Elmer – Samarium
328.90$Instrument Perkin Elmer Atomic Absorption Spectrocopy Pin Type / Connectivity Twelve (12) Pin ~ Coded Wavelength Primary Wavelength 429.7nm Alternative Wavelengths 476.0nm Optical Window material Quartz -
P947LL – Hollow Cathode Lamp (HCL) to suit Cableless Perkin Elmer – Samarium
499.00$Instrument Perkin Elmer Atomic Absorption Spectroscopy (AAnalyst Series of Instruments) Pin Type / Connectivity Four (4) Pin ~ Cableless Notes This lamp also features EPROM for digital coding Wavelength Primary Wavelength 429.7nm Alternative Wavelengths 476.0nm Optical Window material Quartz -
P948 – Hollow Cathode Lamp (HCL) to suit Perkin Elmer – Scandium
299.00$Instrument Perkin Elmer Atomic Absorption Spectrometer (AAS) Pin Type / Connectivity Nine (9) Pin ~ Standard Wavelength Primary Wavelength 391.2nm Alternative Wavelengths 390.8nm Optical Window material Quartz -
P948C – Hollow Cathode Lamp (HCL) to suit Coded Perkin Elmer – Scandium
328.90$Instrument Perkin Elmer Atomic Absorption Spectrocopy Pin Type / Connectivity Twelve (12) Pin ~ Coded Wavelength Primary Wavelength 391.2nm/td> Alternative Wavelengths 390.8nm Optical Window material Quartz -
P948LL – Hollow Cathode Lamp (HCL) to suit Cableless Perkin Elmer – Scandium
499.00$Instrument Perkin Elmer Atomic Absorption Spectroscopy (AAnalyst Series of Instruments) Pin Type / Connectivity Four (4) Pin ~ Cableless Notes This lamp also features EPROM for digital coding Wavelength Primary Wavelength 391.2nm/td> Alternative Wavelengths 390.8nm Optical Window material Quartz -
P949 – Hollow Cathode Lamp (HCL) to suit Perkin Elmer – Selenium
328.90$Instrument Perkin Elmer Atomic Absorption Spectrometer (AAS) Pin Type / Connectivity Nine (9) Pin ~ Standard Wavelength Primary Wavelength 196.0nm Alternative Wavelengths 204.0nm Optical Window material Quartz -
P949C – Hollow Cathode Lamp (HCL) to suit Coded Perkin Elmer – Selenium
328.90$Instrument Perkin Elmer Atomic Absorption Spectrocopy Pin Type / Connectivity Twelve (12) Pin ~ Coded Wavelength Primary Wavelength 196.0nm Alternative Wavelengths 204.0nm Optical Window material Quartz -
P949LL – Hollow Cathode Lamp (HCL) to suit Cableless Perkin Elmer – Selenium
499.00$Instrument Perkin Elmer Atomic Absorption Spectroscopy (AAnalyst Series of Instruments) Pin Type / Connectivity Four (4) Pin ~ Cableless Notes This lamp also features EPROM for digital coding Wavelength Primary Wavelength 196.0nm Alternative Wavelengths 204.0nm Optical Window material Quartz -
P950 – Hollow Cathode Lamp (HCL) to suit Perkin Elmer – Silicon
299.00$Instrument Perkin Elmer Atomic Absorption Spectrometer (AAS) Pin Type / Connectivity Nine (9) Pin ~ Standard Wavelength Primary Wavelength 251.6nm Alternative Wavelengths 250.7 ~ 251.4nm Optical Window material Quartz -
P950C – Hollow Cathode Lamp (HCL) to suit Coded Perkin Elmer – Silicon
328.90$Instrument Perkin Elmer Atomic Absorption Spectrocopy Pin Type / Connectivity Twelve (12) Pin ~ Coded Wavelength Primary Wavelength 251.6nm Alternative Wavelengths 250.7 ~ 251.4nm Optical Window material Quartz -
P950LL – Hollow Cathode Lamp (HCL) to suit Cableless Perkin Elmer – Silicon
429.00$Instrument Perkin Elmer Atomic Absorption Spectroscopy (AAnalyst Series of Instruments) Pin Type / Connectivity Four (4) Pin ~ Cableless Notes This lamp also features EPROM for digital coding Wavelength Primary Wavelength 251.6nm Alternative Wavelengths 250.7 ~ 251.4nm Optical Window material Quartz -
P951 – Hollow Cathode Lamp (HCL) to suit Perkin Elmer – Silver
279.00$Instrument Perkin Elmer Atomic Absorption Spectrometer (AAS) Pin Type / Connectivity Nine (9) Pin ~ Standard Wavelength Primary Wavelength 328.1nm Alternative Wavelengths 338.3nm Optical Window material Quartz -
P951C – Hollow Cathode Lamp (HCL) to suit Coded Perkin Elmer – Silver
306.90$Instrument Perkin Elmer Atomic Absorption Spectrocopy Pin Type / Connectivity Twelve (12) Pin ~ Coded Wavelength Primary Wavelength 328.1nm Alternative Wavelengths 338.3nm Optical Window material Quartz -
P952 – Hollow Cathode Lamp (HCL) to suit Perkin Elmer – Sodium
279.00$Instrument Perkin Elmer Atomic Absorption Spectrometer (AAS) Pin Type / Connectivity Nine (9) Pin ~ Standard Wavelength Primary Wavelength 589.0nm Alternative Wavelengths 330.2 ~ 589.6nm Optical Window material Quartz -
P952C – Hollow Cathode Lamp (HCL) to suit Coded Perkin Elmer – Sodium
306.90$Instrument Perkin Elmer Atomic Absorption Spectrocopy Pin Type / Connectivity Twelve (12) Pin ~ Coded Wavelength Primary Wavelength 589.0nm Alternative Wavelengths 330.2 ~ 589.6nm Optical Window material Quartz -
P953 – Hollow Cathode Lamp (HCL) to suit Perkin Elmer – Strontium
299.00$Instrument Perkin Elmer Atomic Absorption Spectrometer (AAS) Pin Type / Connectivity Nine (9) Pin ~ Standard Wavelength Primary Wavelength 460.7nm Alternative Wavelengths 407.8m Optical Window material Quartz -
P953C – Hollow Cathode Lamp (HCL) to suit Coded Perkin Elmer – Strontium
328.90$Instrument Perkin Elmer Atomic Absorption Spectrocopy Pin Type / Connectivity Twelve (12) Pin ~ Coded Wavelength Primary Wavelength 460.7nm Alternative Wavelengths 407.8m Optical Window material Quartz -
P954 – Hollow Cathode Lamp (HCL) to suit Perkin Elmer – Tantalum
299.00$Instrument Perkin Elmer Atomic Absorption Spectrometer (AAS) Pin Type / Connectivity Nine (9) Pin ~ Standard Wavelength Primary Wavelength 271.5nm Alternative Wavelengths 275.8nm Optical Window material Quartz -
P954C – Hollow Cathode Lamp (HCL) to suit Coded Perkin Elmer – Tantalum
328.90$Instrument Perkin Elmer Atomic Absorption Spectrocopy Pin Type / Connectivity Twelve (12) Pin ~ Coded Wavelength Primary Wavelength 271.5nm Alternative Wavelengths 275.8nm Optical Window material Quartz -
P955 – Hollow Cathode Lamp (HCL) to suit Perkin Elmer – Tellurium
299.00$Instrument Perkin Elmer Atomic Absorption Spectrometer (AAS) Pin Type / Connectivity Nine (9) Pin ~ Standard Wavelength Primary Wavelength 214.3nm Alternative Wavelengths 225.9nm Optical Window material Quartz -
P955C – Hollow Cathode Lamp (HCL) to suit Coded Perkin Elmer – Tellurium
328.90$Instrument Perkin Elmer Atomic Absorption Spectrocopy Pin Type / Connectivity Twelve (12) Pin ~ Coded Wavelength Primary Wavelength 214.3nm Alternative Wavelengths 225.9nm Optical Window material Quartz -
P956 – Hollow Cathode Lamp (HCL) to suit Perkin Elmer – Terbium
299.00$Instrument Perkin Elmer Atomic Absorption Spectrometer (AAS) Pin Type / Connectivity Nine (9) Pin ~ Standard Wavelength Primary Wavelength 432.7nm Alternative Wavelengths 431.9 ~ 433.8nm Optical Window material Quartz -
P956C – Hollow Cathode Lamp (HCL) to suit Coded Perkin Elmer – Terbium
328.90$Instrument Perkin Elmer Atomic Absorption Spectrocopy Pin Type / Connectivity Twelve (12) Pin ~ Coded Wavelength Primary Wavelength 432.7nm Alternative Wavelengths 431.9 ~ 433.8nm Optical Window material Quartz -
P957 – Hollow Cathode Lamp (HCL) to suit Perkin Elmer – Thallium
299.00$Instrument Perkin Elmer Atomic Absorption Spectrometer (AAS) Pin Type / Connectivity Nine (9) Pin ~ Standard Wavelength Primary Wavelength 276.7nm Alternative Wavelengths 258.0nm Optical Window material Quartz -
P957C – Hollow Cathode Lamp (HCL) to suit Coded Perkin Elmer – Thallium
328.90$Instrument Perkin Elmer Atomic Absorption Spectrocopy Pin Type / Connectivity Twelve (12) Pin ~ Coded Wavelength Primary Wavelength &276.7nm Alternative Wavelengths 258.0nm Optical Window material Quartz -
P959 – Hollow Cathode Lamp (HCL) to suit Perkin Elmer – Thulium
299.00$Instrument Perkin Elmer Atomic Absorption Spectrometer (AAS) Pin Type / Connectivity Nine (9) Pin ~ Standard Wavelength Primary Wavelength 371.8nm Alternative Wavelengths 436.0 ~ 410.6nm Optical Window material Quartz -
P959C – Hollow Cathode Lamp (HCL) to suit Coded Perkin Elmer – Thulium
328.90$Instrument Perkin Elmer Atomic Absorption Spectrocopy Pin Type / Connectivity Twelve (12) Pin ~ Coded Wavelength Primary Wavelength 371.8nm Alternative Wavelengths 436.0 ~ 410.6nm Optical Window material Quartz -
P960 – Hollow Cathode Lamp (HCL) to suit Perkin Elmer – Tin
299.00$Instrument Perkin Elmer Atomic Absorption Spectrometer (AAS) Pin Type / Connectivity Nine (9) Pin ~ Standard Wavelength Primary Wavelength 235.5nm Alternative Wavelengths 224.6 ~ 266.1nm Optical Window material Quartz -
P960C – Hollow Cathode Lamp (HCL) to suit Coded Perkin Elmer – Tin
328.90$Instrument Perkin Elmer Atomic Absorption Spectrocopy Pin Type / Connectivity Twelve (12) Pin ~ Coded Wavelength Primary Wavelength 235.5nm Alternative Wavelengths 224.6 ~ 266.1nm Optical Window material Quartz -
P961 – Hollow Cathode Lamp (HCL) to suit Perkin Elmer – Titanium
279.00$Instrument Perkin Elmer Atomic Absorption Spectrometer (AAS) Pin Type / Connectivity Nine (9) Pin ~ Standard Wavelength Primary Wavelength 364.3nm Alternative Wavelengths 365.4 ~ 399.0nm Optical Window material Quartz -
P961C – Hollow Cathode Lamp (HCL) to suit Coded Perkin Elmer – Titanium
306.90$Instrument Perkin Elmer Atomic Absorption Spectrocopy Pin Type / Connectivity Twelve (12) Pin ~ Coded Wavelength Primary Wavelength 364.3nm Alternative Wavelengths 365.4 ~ 399.0nm Optical Window material Quartz -
P962 – Hollow Cathode Lamp (HCL) to suit Perkin Elmer – Tungsten
299.00$Instrument Perkin Elmer Atomic Absorption Spectrometer (AAS) Pin Type / Connectivity Nine (9) Pin ~ Standard Wavelength Primary Wavelength 255.1nm Alternative Wavelengths 294.7 ~ 400.9nm Optical Window material Quartz